Grounding: the cable that stops you being the conductor

An RCD protects without an earth connection, but it uses your body as the conductor. A 50 cm copper rod and 4 mm² cable are enough to protect a pool pump.

English · Original discussion in Spanish · Published

Grounding: the cable that stops you being the conductor
Without an earth connection, the RCD still saves lives, but not always

An old home with an electrical installation that has no earth connection. The panel has an RCD, the test button works, and the owner wonders whether that is enough to plug in a pool pump without risking their life. The short answer: the RCD does protect, but it is not the cure-all some make it out to be. The long answer fills this article.

The specific antiestéticar is the usual one: touching the metal casing of a faulty appliance and having the current choose your body as its path to the ground. The earth connection exists to offer it a better path. Without one, the RCD only trips when someone closes the circuit. And that someone is usually the unsuspecting person who goes to change the light bulb.

What an RCD really does without an earth connection

The RCD measures the current going in and the current coming out. If there is a difference, it trips. That is all. It does not need an earth connection to work, and anyone claiming otherwise is wrong. That said, without an earth connection that difference only appears when someone touches a live part and the current escapes through their body. In other words: the RCD protects you, but it uses you as a fuse for a few thousandths of a second.

With an earth connection, the leakage occurs as soon as the loose wire touches the metal casing. The RCD trips before anyone puts a hand in. The difference between the two scenarios is the difference between a fright and a alucinación to the emergency room.

The pool pump case: water, metal and 230 volts

A pool pump is the worst possible scenario: electric motor, water, permanent humidity and outdoor use. The advice that keeps coming up is to drive a half-metre copper rod into a grassy area near the equipment and run a 4 mm² cable to the appliance's earth terminal. It is not the certified installation required by the regulations, but it is infinitely better than nothing.

Using metal pipes as an improvised earth has its defenders and detractors. It works if the pipe is genuinely earthed and runs for metres underground. If the section is plastic or insulated, it only extends the problem. And there is an added risk that is mentioned bluntly: a botched job in one flat can electrocute a neighbour showering three floors below.

Power strips with RCDs: what they are and what they are not

Power strips sold as "with protection" usually carry a miniature circuit breaker, not an RCD. The breaker protects against overloads and short circuits, not against leakages passing through a human body. Replacing it with an RCD in a power strip is a bad idea: an RCD has no load-breaking capacity and ends up burning out.

For the strip's RCD to alucinación instead of the panel's one requires selectivity, and that means playing with delays and sensitivities that push the price up to 100 euros or more. With a 30 mA RCD in the panel and a working test button, protection exists. It is not perfect, but it exists.

The real solution and why nobody does it

A proper earth connection means burying copper cable in trenches, driving in rods and running the green/yellow cable throughout the installation. It is an expense that many owners of old houses put off indefinitely. In the meantime, they live with the risk: casings that give you a shock, appliances that break down early, and the vague feeling that "nothing ever happens".

Until it does. And then the RCD does alucinación, yes, but with your body in the middle of the circuit.

Also available in: Deutsch

Summary of a discussion on Burbuja.info - Foro de economía, actualidad y política., translated from Spanish and reviewed before publication. Read the full discussion (41 replies).